Any questions?

We’re here to help!

Please give us a call »

Bürkert - Close to you
Office /2
    • Main Office
      Burkert Contromatic Inc.
      5002 South Service Road
      Burlington, Ontario L7L 5Y7
      Phone +1 905 632 3033
      Fax +1 905 632 3833
      E-Mail fnyrf.pn@ohexreg.pbz
    • Office
      Montreal Sales Center Bürkert Contromatic Inc.
      8104 Trans Canada Highway
      St. Laurent, Quebec H4S 1M5
      Phone +1 514 336 9033
      Fax +1 514 336 9034
      E-Mail fnyrf.pn@ohexreg.pbz
  • Main Office
  • Headquarters
  • Systemhaus
  • Distributor
  • Office
  • Plant
  • Logistic center
bürkert
We make ideas flow.
We make ideas flow.

    Type 8750 - Flow Rate Controller, flow control system for gases

    Produkt-Foto Typ 8750

    Specific products may differ slightly from the general images shown.

    • Produkt-Foto Typ 8750
    • Produkt-Foto Typ 8750

    Type Description

    The flow rate controller, Type 8750, is a system to measure and control gases using the differential pressure principle. The reliable and robust system consists of an ELEMENT continuous control valve, Type 2301, with the compact process controller Type 8693 and two pressure transmitters, Type 8323. These components are supplied within an assembled system including a special body. The Bürkert flow rate controller does not need a separate flow meter. The control valve serves as orifice plate. From the pressure difference across the valve and the given density and temperature a nominal flow can be calculated. Therefore the flow characteristics of the valve are given to the process controller. The volume flow can then be adjusted by changing the stroke of the control valve. All components of the control loop build an integrated system. The flow rate controller offers a high repeatability and large measuring range. With the combination of orifice plate and control valve the pressure drop is reduced in comparison to conventional solutions. With the variable orifice of the control valve the measurement range is increased. Low assembly costs and easy commissioning are further advantages of this unique system.

    • Reliable, robust system
    • Reduced interfaces
    • Orifice plate and actuator in one
    • Easy operation
    • Fit for stand-alone operation

    To help select the correct product please refer to the technical data, images and notes for proper use found in the data sheet.

    Downloads

    Data Sheets

    Description
    Filesize
    Language / Country
    DTS Type 8750 data sheet | Durchflussreglungssystem for gases 965.5 kB EN / EU
    DTS Typ 8750 Datenblatt | Durchflussreglungssystem für Gase 668.1 kB DE / DE

    User Manuals

    Description
    Filesize
    Language / Country
    MAN Additional manual Type 6013 |PX01 - PX03 Use in the explosion-hazard area 125 kB EN,FR,DE / EU
    MAN Quickstart Type 8750 | Classic with Type 8693, Flow controller 2.6 MB EN / EU
    MAN Quickstart Type 8750 | Flow controller 1.7 MB EN / EU
    MAN Quickstart Type 8750 | Flow controller 553 kB EN / EU
    MAN Quick Start Tipo 8750 | Cabezal de control para válvulas higiénicas de proceso 2.1 MB ES / ES
    MAN Quickstart Typ 8750 | Classicmit Typ 8693 Fluid-Mengen-Regler 1.7 MB DE / DE
    MAN Quickstart Typ 8750 | Fluid-Mengen-Regler 538 kB DE / DE
    MAN Quickstart Typ 8750 | Fluidmengenregler 1.7 MB DE / DE
    MAN Quickstart Type 8750 | Classic avec 8693, Systèm de régulation de débits de fluide FMR 2.5 MB FR / FR
    MAN Quickstart Type 8750 | Systèmde régulation de débits de fluide 1.8 MB FR / FR
    MAN Quickstart Type 8750 | Système de régulation de débits de fluide 584 kB FR / EU

    Software

    Description
    Filesize
    Language / Country
    SOW Init Files EDS GSD GSDML EDD A.08 845.1 kB ML

    EU Declaration

    Description
    Filesize
    Language / Country
    ABD EU-DoC|EU Declaration 1.5 MB EN,FR,DE

    My Comparison List