Any questions?

We’re here to help!

Please give us a call »

Bürkert - Close to you
Office /2
    • Main Office
      Burkert Contromatic Inc.
      5002 South Service Road
      Burlington, Ontario L7L 5Y7
      Phone +1 905 632 3033
      Fax +1 905 632 3833
      E-Mail fnyrf.pn@ohexreg.pbz
    • Office
      Montreal Sales Center Bürkert Contromatic Inc.
      8104 Trans Canada Highway
      St. Laurent, Quebec H4S 1M5
      Phone +1 514 336 9033
      Fax +1 514 336 9034
      E-Mail fnyrf.pn@ohexreg.pbz
  • Main Office
  • Headquarters
  • Systemhaus
  • Distributor
  • Office
  • Plant
  • Logistic center
bürkert
We make ideas flow.
We make ideas flow.

    Type MS05 - Turbidity Sensor Cube

    Produkt-Foto Typ MS05

    Specific products may differ slightly from the general images shown.

    • Produkt-Foto Typ MS05
    • Produkt-Foto Typ MS05
    • Produkt-Foto Typ MS05

    Type Description

    The device is a turbidity measurement sensor. It is used within the Online Analysis System Type 8905 by being plugged into a spare fluidic backplane slot. The device contains an optical sensor following DIN EN ISO 7027 or optional according to EPA methode 180.1. The turbidity of water needs to be analysed continuously as indicator for unwanted undissolved content in the water. Measurement prior and post filtration indicates the effect of filtration and may help to optimise the filter backwash process. In the best case it can lead to water and energy savings. The electrical and fluidic connections are made via the connection panel of the system. The sensor cube is communicating via büS, so the recognition at the Online Analysis System is fully automatic. When plugged into a system you will find the sensor in the list of büS members for further customized adjustments.

    • Fully compatible with büS systems and a wide range of further analysis sensor cubes
    • Optical sensor according to DIN EN ISO 7027 or EPA Methode 180.1
    • Modular sensor cube for hot swap (exchange during operation)
    • Minimal sample water flow needed

    To help select the correct product please refer to the technical data, images and notes for proper use found in the data sheet.

    Applications & Tools

    CAD Model

    Cookies must be enabled to use this function. Please accept cookie privacy policy first.


    Downloads

    Data Sheets

    Description
    Filesize
    Language / Country
    DTS Type 8905 data sheet | onlineanalysis system 764.7 kB EN / EU
    DTS Type MS05 data sheet | turbidity sensor cube 2.2 MB EN / EU
    DTS Typ 8905 Datenblatt | EDIP-Online-Analysesystem 767.6 kB DE / DE
    DTS Typ MS05 Datenblatt | Sensor-Cube zur Trübungsmessung 2.2 MB DE / DE
    DTS Type 8905 fiches techniques |Système d'analyse en ligne, conception EDIP 765.5 kB FR / FR
    DTS Type MS05 fiches techniques |Module capteur de turbidité 2.2 MB FR / FR

    User Manuals

    Description
    Filesize
    Language / Country
    MAN Operating Instructions Type 8905 | Online analysis system 2 MB EN / EU
    MAN Operating Instructions Type MS05 | Turbidity sensor cube 1.9 MB EN / EU
    MAN Bedienungsanleitung Typ 8905 | Online-Analyse-System 2 MB DE / EU
    MAN Bedienungsanleitung Typ MS05 | Trübung-Sensor-Cube 1.9 MB DE / EU
    MAN Manuel d?utilisation Type 8905 | Système d'analyse en ligne 2.1 MB FR / EU
    MAN Manuel d?utilisation Type MS05 | Module capteur de turbidité 1.9 MB FR / EU

    My Comparison List